INCREASING ENERGY EFFICIENCY WITH USE IN WATERS MAGNETISATION A STEAM POWER GENERATORS IN SUGAR INDUSTRY

Authors

  • MSc. María de Lourdes de la Cruz-Aragone Departamento de Ingeniería Química, Facultad de Química, Universidad de Camagüey
  • Dra. Martha Nápoles-García Departamento de Ingeniería Química, Facultad de Química, Universidad de Camagüey

DOI:

https://doi.org/10.1590/2224-6185.2011.2.%25x

Keywords:

magnetization, corrosion, inlays, thermal surfaces, boilers, energetic improvement

Abstract

This paper deals with the evaluation of magnetic treatment effect in boiler feeding water for avoiding formation of inlays and negative corrosion effects. This work is developed in Siboney
sugar mill, in Camaguey, Cuba. Magnetic treatment effectiveness is demonstrated, because of useful life of exposed metallic surfaces is increased and corrosion effects decreased. It is proved because there was slight deposition in form of a fine send. Kinetic parameters and inlay characterization show in all cases significant when implementing hypothesis test. This result permits to save energy as well as fuel and provides a very important environmental effect.

Published

2016-03-01

How to Cite

de la Cruz-Aragone, M. M. de L., & Nápoles-García, D. M. (2016). INCREASING ENERGY EFFICIENCY WITH USE IN WATERS MAGNETISATION A STEAM POWER GENERATORS IN SUGAR INDUSTRY. Chemical Technology, 31(2), 64–69. https://doi.org/10.1590/2224-6185.2011.2.%x

Issue

Section

Artículos

Most read articles by the same author(s)