ANALYTICAL DETERMINATION COEFFICIENT TOTAL RESISTANCE FLOW DYNAMICS MOVEMENT OF NATURAL CIRCULATION STEAM GENERATOR

  • Luis Vázquez Seisdedos Universidad de Oriente
  • Luis Oliva Ruiz Universidad de Oriente
  • Edward E. Madariaga Santaló Central Termoeléctrica "Antonio Maceo" (Renté)
  • Antonio Pons Hernández Universidad de Oriente
  • Pedro Pacheco Bertot Universidad de Oriente
Keywords: process modeling, hydrodynamics of the generator of vapor of natural circulation

Abstract

It is formulated analytically the determination of the coefficient of total resistance to the fluid in the dynamics of the movement of the natural circulation of generator of vapor in function of the
constructive parameters of the hydraulic circuit and the values of the fundamental variables of operation. The discussed results correspond to real data of the Thermoelectric Power Station
“Antonio Maceo” of Santiago de Cuba city. The calculations are executed automatically by means of functions developed on Matlab.
Published
2017-01-03
How to Cite
Vázquez Seisdedos, L., Oliva Ruiz, L., Madariaga Santaló, E. E., Pons Hernández, A., & Pacheco Bertot, P. (2017). ANALYTICAL DETERMINATION COEFFICIENT TOTAL RESISTANCE FLOW DYNAMICS MOVEMENT OF NATURAL CIRCULATION STEAM GENERATOR. Chemical Technology, 28(1), 41-46. https://doi.org/10.1590/2224-6185.2008.1.%x
Section
Artículos

Most read articles by the same author(s)